Cisco 300-415 Exam Dumps

Implementing Cisco SD-WAN Solutions (300-415 ENSDWI)
955 Reviews

Exam Code 300-415
Exam Name Implementing Cisco SD-WAN Solutions (300-415 ENSDWI)
Questions 173
Update Date November 01,2024
Price Was : $81 Today : $45 Was : $99 Today : $55 Was : $117 Today : $65

Prepare Cisco 300-415 Implementing Cisco SD-WAN Solutions (300-415 ENSDWI)

This exam is a key step towards achieving your Cisco certification in the service provider domain. At Prep4Cisco, we are dedicated to providing you with the most comprehensive study materials and resources to ensure your success in this important certification exam.

Start Your Cisco 300-415 Journey Today

Take the first step towards becoming a certified Cisco service provider professional. With Prep4Cisco's comprehensive study materials and 100% passing guarantee, you'll be well-prepared to excel on the Cisco 300-415 exam. Start your journey today and unlock exciting career opportunities in the world of service provider networking.

Choose Prep4Cisco and let's achieve your Cisco certification goals together!


Cisco 300-415 Sample Questions

Question # 1

In a customer retail network with multiple data centers, what does the network administrator use to create a regional hub topology?

A. control policy on vManage 
B. control policy on vSmart 
C. data policy on vSmart 
D. app route policy on vSmart 



Question # 2

Which component of the Cisco SD-WAN secure extensible network provides a single pane of glass approach to network monitoring and configuration?

A. APIC-EM 
B. vSmart
 C. vManage 
D. vBond 



Question # 3

What is the minimum Red Hat Enterprise Linux operating system requirement for a Cisco SD-WAN controller deployment via KVM? 

A. RHEL7.5 
B. RHEL 6.5 
C. RHEL4.4 
D. RHEL 6.7 



Question # 4

Which two metrics must a cloud Edge router use to pick the optimal path for a SaaS application reachable via a gateway site? (Choose two.) 

A. HTTP loss and latency metrics to the SaaS application 
B. ICMP loss and latency metrics to the SaaS application
C. BFD loss and latency metrics to the gateway site 
D. BFD loss and latency metrics to the SaaS application 
E. HTTP loss and latency metrics to the gateway site



Question # 5

An engineer is configuring a data policy for IPv4 prefixes for a single WAN Edge device on a site with multiple WAN Edge devices How is this policy added using the policy configuration wizard?

A. ln vManage NMS, select the configure policies screen, select the localized policy tab and click add policy 
B. In vSmart controller, select the configure policies screen, select the localized policy tab. and click add policy 
C. In vManage NMS. select the configure policies screen select the centralized policy tab and click add policy 
D. In vBond orchestrator. select the configure policies screen, select the localized policy tab. and click add policy 



Question # 6

WAN Edge routers are configured manually to use UDP port offset to use nondefault offset values when IPsec tunnels are created. What is the offse range?

A. 1-19
 B. 0-18 
C. 0-19 
D. 1-18



Question # 7

Which plane builds and maintains the network topology and makes decisions on traffic flows?

A. orchestration 
B. management 
C. control 
D. data 



Question # 8

Which protocol is configured on tunnels by default to detect loss, latency, jitter, and path failures in Cisco SD-WAN? 

A. TLS 
B. BFD 
C. OMP 
D. BGP 



Question # 9

Which policy tracks path characteristics such as loss, latency, and jitter in vManage?

A. VPN 
B. control 
C. app-route 
D. data 



Question # 10

What is the procedure to upgrade all Cisco SD-WAN devices to a recent version?

A. The upgrade is performed for a group of WAN Edge devices first to ensure data-plabe availability when other controllers are updated. 
B. The upgrade is performed first on vManage, then on WAN Edge devices, then on vBond and finally on vSmart The reboot must start from WAN Edge devices. 
C. Upgrade and reboot are performed first on vManage then on vBond then on vSmart. and finally on the Cisco WAN Edge devices. 
D. Upgrade and reboot are performed first on vBond. then on vSmart. and finally on the Cisco WAN Edge devices.